Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Abb CA4-10 Contact Aux 1NO for AF09-AF96
Abb CA4-10 Contact Aux 1NO for AF09-AF96
Brand:
ABB
Model:
CA4-10
Image
Image
Product Description

Abb CA4-10 Contact Aux 1NO for AF09-AF96

  • Extended Product Type:CA4-10
  • Product ID:1SBN010110R1010
  • EAN:3471523130005
  • Catalog Description:CA4-10 Auxiliary Contact Block
  • Long Description:CA4-10 is a 1-pole front mounted auxiliary contact block equipped with screw terminals and can be fitted on AF(C)09(Z)(B)...96 contactors and NF(C)(Z)(B) contactor relays. CA4-10 is available with 1 N.O. instantaneous contacts for standard industrial environments.
  • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
  • Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
  • Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
  • Rigid Solid 1/2x 1 ... 2.5 mm²
  • Rigid Stranded 1/2x 1 ... 2.5 mm²
  • Maximum Electrical Switching Frequency:(AC-15) 1200 cycles per hour
  • (DC-13) 900 cycles per hour
  • Maximum Mechanical Switching Frequency:3600 cycles per hour
  • Mounted Auxiliary Contacts:1 NO, 0 NC
  • Mounting Type:Front mounting
  • Number of Auxiliary Contacts NC:0
  • Number of Auxiliary Contacts NO:1
  • Number of Poles:1
  • Rated Frequency (f):Auxiliary Circuit 50 / 60 Hz
  • Rated Impulse Withstand Voltage (Uimp):6 kV
  • Rated Insulation Voltage (Ui):acc. to IEC 60947-5-1 690 V
  • acc. to UL/CSA 600 V
  • Rated Operational Current AC-15 (Ie):(500 V) 2 A
  • (690 V) 2 A
  • (24 / 127 V) 6 A
  • (220 / 240 V) 4 A
  • (400 / 440 V) 3 A
  • Rated Operational Current DC-13 (Ie):(24 V) 6 A / 144 W
  • (48 V) 2.8 A / 134 W
  • (72 V) 1 A / 72 W
  • (110 V) 0.55 A / 60 W
  • (125 V) 0.55 A / 69 W
  • (220 V) 0.27 A / 60 W
  • (250 V) 0.27 A / 68 W
  • (400 V) 0.15 A / 60 W
  • (500 V) 0.13 A / 65 W
  • (600 V) 0.1 A / 60 W
  • Rated Operational Voltage:Auxiliary Circuit 690 V
  • Rated Short-time Withstand Current Low Voltage (Icw):for 0.1 s 140 A
  • for 1 s 100 A
  • Standards:IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14
  • Suitable For:AF09
  • AF09Z
  • AF12
  • AF12Z
  • AF16
  • AF16Z
  • AF26
  • AF26Z
  • AF30
  • AF30Z
  • AF38
  • AF38Z
  • AF40
  • AF52
  • AF65
  • AF80
  • AF96
  • AFC09
  • AFC12
  • AFC16
  • AFC26
  • AFC30
  • AFC38
  • AFC40
  • AFC52
  • AFC65
  • AFC80
  • AFC96
  • AF09B
  • AF09ZB
  • AF12B
  • AF12ZB
  • AF16B
  • AF16ZB
  • AF26B
  • AF26ZB
  • AF30B
  • AF30ZB
  • AF38B
  • AF38ZB
  • AF40B
  • AF52B
  • AF65B
  • AF80B
  • AF96B
  • NF22E
  • NFZ22E
  • NF31E
  • NFZ31E
  • NF40E
  • NFZ40E
  • NFC22E
  • NFC31E
  • NFC40E
  • NFZB22E
  • NFB22E
  • NFZB31E
  • NFB31E
  • NFZB40E
  • NFB40E
  • Terminal Type:Screw Terminals
  • Tightening Torque:Auxiliary Circuit 1.2 N·m
  • Wire Stripping Length:Auxiliary Circuit 10 mm
  • Unit of Measurement : Pcs
S$ 8.80
(exc. GST)
S$ 9.59
(inc. GST)
Quantity:
EA
Stock:
11 EA in stock
location
In Seller's Warehouse
Shop by Specification Table
You can find items with similar specifications from the table below.
Auxiliary Contact
57 Items
auxiliary-contact-img
Rated Current
6 A at 120 V AC-15 3 A at 240 V AC-15 1.8 A at 400 V AC-15 1.5 A at 480 V AC-15 2.8 A at 24 V DC-13 1.4 A at 48 V DC-13 0.55 A at 125 V DC-13 0.27 A at 250 V DC-13 0.15 A at 400 V DC-13, AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC, DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, AC-12 3 A at 380...415 V, AC 50/60 Hz AC-12 6 A at 220...240 V, AC 50/60 Hz DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC
Range
TeSys D, Acti 9, C6-, Tesys, Multi 9
Standard
EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1, IEC 60947-3, IEC 60947-5, EN/IEC 60947-5-1, UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN/IEC 60947-5-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-1 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947-1, 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1, 500 V, 400 V
IP Degree of Protection
IP2X conforming to IEC 60529, IP2X, IP20 conforming to IEC 60529, IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529, IP20 conforming to EN/IEC 60947-5-1
Ambient Air Temperature for Operation
-5…60 °C, -25…50 °C, -20…50 °C, -35…70 °C, -25…60 °C
Ambient Air Temperature for Storage
-50…80 °C, -50…70 °C, -40…85 °C, -60…80 °C, -40…70 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Auxiliary Contact from ABB
Source & compare similar products
More from Auxiliary Contact
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top