Product fulfills requirements according to UN/ECE R118
Ethernet CAT5
Male straight – male straight
RJ45 – RJ45, 4-pole
shielded
Further cable lengths on request.
Plastic housings with good resistance against chemicals and oils.
The resistance to aggressive media should be individually tested for your application
Cable Length
Side 1
- Mounting method: inserted
- Family construction form: RJ45
- No. of poles: 4
Electrical Data | Supply
- Operating voltage DC max.: 60 V
- Current operating per contact max.: 1,5 A
Industrial Communication
- Transfer parameters: CAT5e, Class D (ISO/IEC 11801:2002), (EN 50173-1)
- Data transmission rate max.: 100 MBit/s
Industrial Communication | Ethernet Functionality
Diagnostics
- Status indication LED: no
Device Protection | Electrical
- Degree of protection (EN IEC 60529): IP20
- Pollution Degree: 3
- Rated surge voltage: 1 kV
- Material group (IEC 60664-1): I
Mechanical Data
- Contour for corrugated hose: without
Mechanical Data | Material Data
- Material housing: PUR
- Locking material: PA
Mechanical Data | Mounting Data
- Locking techniques: Snap-in connector
Environmental Characteristics | Climatic
- Operating temperature min.: -25 °C
- Operating temperature max.: 85 °C
- Additional condition temperature range: depending on cable quality
Important Installation Notes
- Note on strain relief: Protect the connectors by suitable measures from mechanical loads, e.g., by using cable ties.
- Note on bending radius: Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Cable Data
- Wire arrangement: white, yellow, blue, orange
General Data | Cable
- Cable identification: 796
- Jacket color: green
- Type of certificate: cURus
Structure | Cable
- Amount stranding: 1
- Stranding: 4 wires around core filler twisted
- Cable shielding (type): copper braid, tinned
- Cable shielding (coverage): 85 %
- Banding: Fleece, foil
- Filler: yes
Mechanical Data | Cable
- Cable weight: 69,3 g/m
- Material jacket: PUR
- Shore hardness jacket: 89 Shore A
- Freedom from ingredients (jacket): lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
- Outer diameter (jacket): 6,7 mm
- Tolerance outer diameter (sheath): ± 5 %
- Material inner jacket: FRNC
- Color (inner jacket): natur
- Material wire insulation: PE
- Amount wires: 4
- Outer diameter insulation: 1,4 mm
- Outer diameter tolerance core insulation: ± 5 %
- Shore hardness wire insulation: 65 Shore D
- Ingredient freeness wire insulation: lead-free, CFC-free, halogen-free
- Amount strands (wire): 7
- Diameter of single wires: 22 AWG
- Conductor cross-section (wire): 22 AWG
- Material conductor wire: Stranded copper wire, bare
Electrical Data | Cable
- Nominal voltage AC max.: 300 V
- Current load capacity (standard): to DIN VDE 0298-4
- Current load capacity min. wire: 4,8 A
- Characteristic impedance: 100 Ω ± 15 % @ 100 MHz
- Electrical resistance line constant wire: 55 Ω/km @ 20 °C
- AC withstand voltage (wire - wire): 2 kV @ 60 s
- Electrical capacity line constant (wire - wire): 50000 pF/km
- Power frequency withstand voltage (wire - jacket): 2 kV @ 60 s
- AC withstand voltage (wire - shield): 2 kV @ 60 s
- Isolation resistance: 5000 MΩ × km
Temperature Range | Cable
- Min. operating temperature (static): -40 °C
- Max. operating temperature (fixed): 80 °C
- Operating temperature min. (dynamic): -30 °C
- Operating temperature max. (dynamic): 70 °C
Resistances | Cable
- Flame resistance: IEC 60332-2-2 | UL 1581 § 1090 | UL 1581 § 1100 FT2
- Chemical resistance: Good, application-related testing
- Gasoline resistance: Good, application-related testing
- Oil resistance: DIN EN 60811-404 | Good, application-related testing
Installation | Cable
- Bending radius (fixed): 5 x Outer diameter
- Bending radius (dynamic): 12 x Outer diameter
- No. of bending cycles (C-track): 3 Mio. @ 25 °C
- Traversing distance (C-track): 5 m @ 25 °C
- Travel speed (C-track): 3,3 m/s @ 25 °C
- No. of torsion cycles: 1 Mio. @ 25 °C
- Torsion stress: ± 180 °/m