Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Murr Elektronik 85135 ECO-rail 2 1P 24Vdc 10A
Murr Elektronik 85135 ECO-rail 2 1P 24Vdc 10A
Image
Image
Image
Product Description

Murr 85135 ECO-rail 2 1P 24Vdc 10A

INPUT: 90...132 V AC/173...264 V AC

OUTPUT: 23...28 V DC

Current: 10 A

Mains failure bridging min.

min. 12 ms (115 V AC); min. 30 ms (230 V AC)

Electrical data

  • Number of devices series connection max.: 2
  • Parallel connection: No
  • Series connection: Yes

Electrical data | Supply

  • Power frequency: 50 ... 60 Hz

Electrical data | Input

  • Fuse protection primary side internal: 5 A
  • Characteristic back-up fuse: Inertia
  • Input voltage 1 AC: 100 V
  • Input voltage 1 AC min.: 90 V
  • Input voltage 1 AC max.: 132 V
  • Input voltage 2 AC: 240 V
  • Input voltage 2 AC min.: 173 V
  • Input voltage 2 AC max.: 264 V
  • Input current at input voltage 1 AC: 4.3 A
  • Input current at input voltage 2 AC: 2.1 A
  • Inrush current max.: 18 A @ 230 V
  • Efficiency: 86 % @ 115 V AC, 87 % @ 230 V AC

Electrical data | Output

  • Output voltage DC: 24 V
  • Output voltage DC min.: 23 V
  • Output voltage DC max.: 28 V
  • Output voltage adjustable: Yes
  • Output current: 10 A
  • Ripple effective max.: 10 mV
  • Spikes (s-s) max.: 50 mV

Device protection | Electrical

  • Degree of protection (EN IEC 60529): IP20
  • Overload protection output: Yes
  • Short-circuit protection output: Yes

Mechanical data | Mounting data

  • Mounting method: Geschnappt
  • Suitable for mounting type: Mounting rail TH35, (EN 60715)
  • Height: 125 mm
  • Width: 68 mm
  • Depth: 125 mm

Environmental characteristics | Climatic

  • Operating temperature min.: 0 °C
  • Operating temperature max.: 40 °C
  • Derating from: 40 °C
  • Storage temperature min.: -20 °C
  • Storage temperature max.: 85 °C
  • Relative humidity min. (operation): 20 %
  • Relative humidity max. (operation): 90 % (no condensation)

Connection type 1

  • Connection: Spring clamp terminals FK
  • Family construction form: Terminal
  • Gender: Female
  • Color contact carrier: Green
  • No. of poles: 3
  • PIN 1: PE
  • PIN 2: N
  • PIN 3: L

Connection type 2

  • Connection: Spring clamp terminals FK
  • Family construction form: Terminal
  • Gender: Female
  • Color contact carrier: Green
  • No. of poles: 4
  • PIN 1: -
  • PIN 2: -
  • PIN 3: +
  • PIN 4: +
S$ 282.10
(exc. GST)
S$ 307.49
(inc. GST)
Image
Lead time of 10 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Power Supply
23 Items
power-supply-img
Standards
CSA C22.2 No 60950-1 UL 508 EN/IEC 62368-1, IEC 62368-1 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 CSA C22.2 No 62368-1 UL 508 CSA C22.2 No 107.1 EN/IEC 62368-1, IEC 62368-1 EN/IEC 61010-1 EN 61010-2-201 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 UL 61010-1 UL 61010-2-201 CSA C22.2 No 62368-1 CSA C22.2 No 61010-1 CSA C22.2 No 61010-2-201 IEC 60335-1 EN/IEC 62368-1, UL 508 CSA C22.2 No 60950-1 EN/IEC 62368-1, CSA C22.2 No 60950-1 UL 508
Connections - Terminals
Removable screw terminal block: 2 x 2.5 mm², for diagnostic relay Screw type terminals: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for input ground connection Screw type terminals: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connection, Screw connection: 0.5...2.5 mm², (AWG 20...AWG 14) for output Screw connection: 0.75...2.5 mm², (AWG 18...AWG 14) for input, For ground connection: screw type terminals, connection capacity: 1 x 4 mm² AWG 12, Removable screw terminal block: 2 x 2.5 mm², for diagnostic relay Screw type terminals: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for input ground connection Screw type terminals: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for output ground connection, For output connection: screw type terminals, connection capacity: 2 x 0.5...2 x 10 mm² AWG 20...AWG 8 For input connection: screw type terminals, connection capacity: 4 x 0.5...4 x 10 mm² AWG 20...AWG 8 For diagnostic relay: removable screw terminal block, connection capacity: 1 x 2.5 mm² AWG 14
Product Certifications
CCSAus EAC UL RCM KC, CE CUL listed CUL recognized RCM CB Scheme EAC KC, CE CULus EAC RCM CB Scheme KC, CCSAus EAC KC RCM UL, EAC RCM
Inrush Current
45 A at 100...240 V AC, 35 A at 115 V 70 A at 230 V, 40.0 A at 115 V 80.0 A at 230 V, 50 A at 100...240 V AC, 30 A
Power Supply Output Current
2.2 A, 2.5 A, 6.25 A, 3.13 A, 5 A
-
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power Supply from Murr Elektronik
Source & compare similar products
More from Power Supply
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top